Data Center Rack Load


Darui Electric recommends for you

Product Introduction


It is well known that when servers are placed in an environment with poor heat dissipation, the lifespan of hard drives will be greatly reduced, and other components of the server will also fail one after another. When modern server motherboards detect CPU overheating, they usually limit the CPU frequency, so even if the server is not completely damaged, it may become unusable. Sometimes, component overheating may cause process crashes.

The data center rack load bank is mainly a purely resistive load that simulates the heat generation and line loading of data servers. It can serve as a heat source similar to rack servers, simulating and testing the cooling system capacity of the computer room and whether the air flow is controllable. It can also test AC power sources such as UPS and backup generator sets, and uses step-by-step segmented power free combination control to realistically restore the energy consumption and heat dissipation of data server IT equipment. By using a data center rack load bank to test the voltage load stability of the data center, ensure the effective operation of the power supply system, data service system, etc.

The data center rack load bank can control the gear under rated voltage to obtain different current levels and on/off times to meet customer usage requirements. The power control panel of the load bank can control the circuit breaker action, and the main circuit of the circuit breaker controls the on/off of the resistive load unit. It also has temperature detection protection function. When the load temperature exceeds the safety threshold, it automatically unloads and alarms. On-site electrical parameter monitoring instruments are provided to monitor all electrical parameters of servers, UPS, generator sets, etc. in real time, and automatically generate various charts, curves, and test reports for a more intuitive understanding of equipment usage.

► Technical Parameters
ModelLB-1KW-380VAC
Rated Power1KW
Test Voltage, FrequencyThree-phase 380VAC/50Hz
Control VoltageSingle-phase 220VAC/50Hz
Power Factor1
Load CharacteristicsPurely Resistive
Load ControlCircuit Breaker Control
Communication InterfaceRS232, 485 Communication
Loading Accuracy±5%
Cooling MethodForced Air Cooling, Front Air Intake, Rear Air Outlet
Protection LevelIP20 (Indoor Environment)
Insulation ClassF, with grounding bolt at the bottom of the chassis
Monitoring FunctionMonitor current and voltage parameters of the test circuit
Dimensions430*177*500mm
Measurement and Control MethodThe box terminal is equipped with a multifunctional display meter, located inside the box, to monitor electrical parameter data
Load Protection1. Emergency Stop: Manual one-key forced unloading, cannot load when emergency stop is locked

2. Temperature Protection: When the load temperature exceeds the safety threshold, automatically unload and alarm


Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Tel: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us