40KV/1.1μF40KV/1.1μF(智能/全自动)VLF Hipot Tester装置-扬州达瑞

全自动Dielectric Loss Tester-扬州达瑞

40KV/1.1μF 40KV/1.1μF (Intelligent/Automatic) Ultra-Low Frequency Withstand Voltage Test Device - Yangzhou Darui

Published: 2018-08-11

Views: 2922

Category: Explosion-proof Heater

Product Description

40KV/1.1μF 40KV/1.1μF (Intelligent/Automatic) Ultra-Low Frequency Withstand Voltage Test Device


Darui Electric recommends for you

Product Features

1. Current, voltage, and waveform data are all directly sampled from the high-voltage side, ensuring data authenticity and accuracy.

2. Overvoltage protection: When the output exceeds the set voltage limit, the instrument will shut down for protection, with an action time of less than 20 milliseconds.

3. Overcurrent protection: Designed with dual protection at both high and low voltage sides. The high-voltage side can perform shutdown protection based on the set value.

4. When the current on the low-voltage side exceeds the rated current, shutdown protection will be triggered, with an action time of less than 20 milliseconds.

5. The high-voltage output protection resistor is designed inside the booster, so no external protection resistor is needed.

6. Due to the use of a high-low voltage closed-loop negative feedback control circuit, the output has no capacitive rise effect.

 



Product Parameters

Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

Load capacity:

0.1 Hz max 1.1F

0.05 Hz max 2.2F

0.02 Hz max 5.5F

Measurement accuracy: 3%

Voltage positive and negative peak error: ≤3%

Voltage waveform distortion: ≤5%

Operating conditions:

Indoor and outdoor;

Temperature: -10℃∽+40℃

Humidity: ≤85% RH

Power supply: AC 50Hz, 220V ±5%




Model



Peak Voltage



Measurement Range



Weight



Application



ZSVLF-40/1.1



40kV



At 0.1Hz ≤1.1μF

At 0.05Hz ≤2.2μF

At 0.02Hz ≤5.5μF



Controller: 4kg 

Booster: 35kg



For cables and generators with voltage 15.75kV and below




Single-phase-to-ground capacitance of different generators



 

Thermal Power



Hydropower



Generator Capacity (MW)



200



300



600



800



125-150



300



400



Single-phase-to-ground Capacitance (μF)



0.2-0.25



0.18-0.26



0.31-0.34



0.69



1.8-1.9



1.7-2.5



2.0-2.5




Capacitance of cross-linked polyethylene insulated single-core power cables (μF/km)




Cross-section mm2 Capacitance μF/km Voltage kV



16



25



35



50



70



95



120



150



185



240



270



10



0.15



0.17



0.18



0.19



0.21



0.24



0.26



0.28



0.32



0.38



-



35



-



-



-



0.11



0.12



0.13



0.14



0.15



0.16



0.17



0.19






Product Introduction

The ZSVLF series ultra-low frequency high voltage generator is a new type of ultra-low frequency AC test device that uses a cosine square wave as the output source. It is mainly used for non-destructive insulation withstand voltage testing of PE (polyethylene)/XLPE (cross-linked polyethylene) plastic power cables in the power sector. It features international advanced level at the end of the 20th century and domestic leading level.

Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Tel: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com